Unspecific reduced blood flow pattern and left ventricular hypertrophy

PTB-XL record 15863, a man aged 68. A public research ECG from Germany, printed on A4, photographed by TraceRead's photo simulator and read end to end. Below is the AI first read, next to the original recording and what the dataset's cardiologists recorded.

0.96

median match with the original recording

0.97 after lining up by up to a tenth of a second

3 of 3

cardiologists' statements that TraceRead AI also flagged

4

extra patterns flagged for the doctor to keep or remove

63

heart rate from the photo, beats a minute

63 on the original recording

The AI first read

What the reading doctor gets

Hover a lead to see how closely the red rebuilt line follows the original recording. Untick the box to see the page without it.

Flattened page of PTB-XL record 15863

Numbers under each lead: how closely the rebuilt line follows the original recording, where 1.00 is a perfect match. Median for this page: 0.96.

Photo usableAI first read, for a doctor to check

PTB-XL record 15863, a man aged 68. A4 paper, 3x4 with one lead II strip, pulses read 4 of 4.

Measures

MeasureFrom the photoOriginal recording
Heart rate (beats a minute)6363
PR interval (ms)136137
QRS width (ms)8887
QT interval (ms)406396
QTc, corrected for heart rate (ms)414404
Heart axis (degrees)2019

Patterns flagged, with TraceRead AI's score

  • Sinus rhythm

    the usual rhythm, started by the heart's natural pacemaker

    95
  • Left ventricular hypertrophy

    the muscle wall of the main pumping chamber may be thicker than usual

    60
  • Unspecific reduced blood flow pattern

    beat changes that can go with reduced blood flow to the heart muscle, without a clear place

    56
  • Reduced blood flow pattern, front and side

    beat changes over the front and side of the heart that can go with reduced blood flow to the heart muscle

    27
  • ST depression

    the middle part of the beat sits lower than usual

    19
  • Unspecific wide QRS

    the signal spreads slowly inside the lower chambers, so the main spike is wide

    7
  • Left atrial enlargement

    the upper left chamber may be larger or under more strain than usual

    2

What the dataset's cardiologists recorded for this ECG

  • Unspecific reduced blood flow pattern
  • Left ventricular hypertrophy
  • Sinus rhythm

Against the cardiologists

TraceRead AI and the dataset's cardiologists, side by side

TraceRead AI flagged 7 patterns. 3 of them are also among the dataset's statements (Sinus rhythm, Left ventricular hypertrophy and Unspecific reduced blood flow pattern). Not in the dataset's statements: Reduced blood flow pattern, front and side, ST depression, Unspecific wide QRS and Left atrial enlargement.

Found by both 3

  • Unspecific reduced blood flow pattern

    Beat changes that can go with reduced blood flow to the heart muscle, without a clear place.

    56
  • Left ventricular hypertrophy

    The muscle wall of the main pumping chamber may be thicker than usual.

    60
  • Sinus rhythm

    The usual rhythm, started by the heart's natural pacemaker.

    95

Recorded by the cardiologists only 0

Nothing: TraceRead AI flagged every statement they recorded.

Flagged by TraceRead AI only 4

  • Reduced blood flow pattern, front and side

    Beat changes over the front and side of the heart that can go with reduced blood flow to the heart muscle.

    27
  • ST depression

    The middle part of the beat sits lower than usual.

    19
  • Unspecific wide QRS

    The signal spreads slowly inside the lower chambers, so the main spike is wide.

    7
  • Left atrial enlargement

    The upper left chamber may be larger or under more strain than usual.

    2

The doctor's review

What the reading doctor would check here

Worked out from this run's own numbers: where the rebuilt line strays, which measures moved, and which flags to keep or remove.

  1. 1The rebuilt line follows the original recording closely in every lead; the lowest match is lead III at 0.90.
  2. 2Every measure from the photo is close to the same measure on the original recording.
  3. 3TraceRead AI flagged 4 patterns the cardiologists did not record: reduced blood flow pattern, front and side, ST depression, unspecific wide QRS and left atrial enlargement. The doctor keeps or removes each one.
  4. 4The calibration pulse looks wider than expected, which would mean a paper speed of about 31.8 millimetres a second. TraceRead still reads the page at 25 millimetres a second, the usual speed, so timings could be a little off if that reading were right.

An AI first read is not the last word.

  • A qualified doctor reviews every AI first read. Nothing reaches a patient until a doctor signs it.
  • Do not rely on TraceRead alone in an emergency.
  • A normal AI first read does not rule out heart disease.
  • For adults, 18 and over.

Stage by stage

How TraceRead read this page

Every step of this run, with what went in and what came out.

Step 1: the photo

On the phone

What went in: one photo of a printed ECG

PTB-XL record 15863, a public research ECG from Germany, was printed as page T-0057 on A4 at 25 mm a second and 10 mm per millivolt. TraceRead's photo simulator then took a photo of it: tilted, lit unevenly, slightly blurred, with sensor noise and JPEG compression, the way a phone camera would.

This record was in PTB-XL's test set, so TraceRead AI never saw it during training. The person was a man aged 68. Age and sex are all TraceRead keeps.

Photo made by computer of the printed PTB-XL record 15863
Shown at 1600 by 1200 pixels.

Step 2: page finder

TraceRead AI

Find the paper and how it is turned

TraceRead AI looks at the whole photo and marks the four corners of the page, and which way up it is. Fixed code then measures the printed millimetre grid to correct the scale and the tilt, and makes the page flat.

Page found
yes
Turned
0 degrees
Paper
A4
The photo with the four page corners TraceRead AI found
The four corners TraceRead AI found, in red.

Step 3: layout reader

TraceRead AI

Work out where each lead sits

Every row of a printout starts with a calibration pulse, a small square step that is 10 mm tall for 1 millivolt. TraceRead AI finds the pulses, and fixed code matches them against 14 known page layouts to work out where each of the 12 leads sits and how long it runs.

Layout
3x4 with one lead II strip
Calibration pulses read
4 of 4
Height of 1 millivolt
10 mm
Paper speed used
25 mm a second
Pulse width suggested
31.8 mm a second
Layout match
0.981

Warnings this step raised

  • The calibration pulse looks wider than expected, which would mean a paper speed of about 31.8 millimetres a second. TraceRead still reads the page at 25 millimetres a second, the usual speed, so timings could be a little off if that reading were right.

Step 4: trace rebuild

TraceRead AI

Rebuild every lead as a digital signal

TraceRead AI marks which pixels are trace ink. Fixed code then follows the ink of each lead, column by column, and turns it into millivolts, 500 points a second. The rebuilt line is drawn back over the paper so a doctor can see at a glance if a lead was misread.

Because this ECG is public, we can check the rebuilt signal against the original recording. 1.00 would be a perfect match; the second number allows the two to be lined up by up to a tenth of a second.

LeadSeconds shownInk foundMatchLined up
I0 to 2.5100%0.980.99
aVR2.5 to 5100%0.960.96
V15 to 7.5100%0.960.97
V47.5 to 10100%0.970.99
II0 to 2.5100%0.991.00
aVL2.5 to 5100%0.940.94
V25 to 7.5100%0.950.96
V57.5 to 10100%1.001.00
III0 to 2.5100%0.900.90
aVF2.5 to 5100%0.970.97
V35 to 7.5100%0.960.97
V67.5 to 10100%1.001.00
II, rhythm strip0 to 100.990.99

Median match for this page: 0.96.

The flattened page with every rebuilt lead drawn over it in red
The flat page with every rebuilt lead drawn over it in red.

Step 5: coverage map

Fixed code

Mark which seconds the paper shows

A 3x4 printout shows each lead for only 2.5 of the 10 seconds the machine recorded. The coverage map tells the pattern finder exactly which seconds of each lead it has, so a part that is not on the paper is never read as a flat line.

I
aVR
V1
V4
II
aVL
V2
V5
III
aVF
V3
V6
II strip
0 s5 s10 s

Step 6: hold for retake

Fixed code

Decide whether the photo can be read

Before any pattern is read, a fixed rule checks the calibration pulses, the layout match and whether leads were cut off. If the rebuilt trace looks unreliable, TraceRead gives no first read and asks for a new photo.

Photo usableThe layout match score was 0.981 (a photo is held back when the score is below 0.888) and 4 of 4 calibration pulses were read. The AI's own uncertainty about the five main heart groups was 0.306 (a photo is held back above 0.497). Neither check fired, so the photo is used.

Step 7: measures

Fixed code

Measure the heartbeat

Fixed code finds every beat, lines the leads up and measures them together. The same code run on the original recording shows how much the photo changed each number, and a reference ECG program from the PTB-XL+ dataset gives a second opinion.

MeasureFrom the photoOriginal recordingReference program
Heart rate (beats a minute)636363
PR interval (ms)136137134
QRS width (ms)888796
QT interval (ms)406396426
QTc, corrected for heart rate (ms)414404433
Heart axis (degrees)201927
PR 150 msQRS 82 msQT 406 ms
The median heartbeat of lead II, from the photo, with the points the PR, QRS and QT measures start and end at.

Step 8: pattern finder

TraceRead AI

Score 71 patterns and flag the ones that pass their line

TraceRead AI reads the 12 rebuilt leads and the coverage map together and scores 71 patterns of rhythm, conduction, thickened heart muscle and ST and T changes. A pattern is flagged when its score passes a line set in advance on other ECGs, never on this one. The lines are set so that patterns are not missed, which is why a pattern can be flagged with a low score, and why some flags are wrong: the doctor decides.

What the dataset's cardiologists recorded for this ECG

  • Unspecific reduced blood flow pattern
  • Left ventricular hypertrophy
  • Sinus rhythm

TraceRead AI flagged 7 patterns. 3 of them are also among the dataset's statements (Sinus rhythm, Left ventricular hypertrophy and Unspecific reduced blood flow pattern). Not in the dataset's statements: Reduced blood flow pattern, front and side, ST depression, Unspecific wide QRS and Left atrial enlargement.

TraceRead AI's score for each pattern, from 0 to 100. The thin line is where that pattern gets flagged.

  • Sinus rhythm

    flagged

    the usual rhythm, started by the heart's natural pacemaker

    95
  • Left ventricular hypertrophy

    flagged

    the muscle wall of the main pumping chamber may be thicker than usual

    60
  • Unspecific reduced blood flow pattern

    flagged

    beat changes that can go with reduced blood flow to the heart muscle, without a clear place

    56
  • Reduced blood flow pattern, front and side

    flagged

    beat changes over the front and side of the heart that can go with reduced blood flow to the heart muscle

    27
  • ST depression

    flagged

    the middle part of the beat sits lower than usual

    19
  • Unspecific wide QRS

    flagged

    the signal spreads slowly inside the lower chambers, so the main spike is wide

    7
  • Left atrial enlargement

    flagged

    the upper left chamber may be larger or under more strain than usual

    2

See TraceRead read a paper ECG

We show you TraceRead reading public research ECGs, step by step, and talk through how your team prints, photographs and reads ECGs today.